Command Reference Guide Frame Relay Sub-Interface Config Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 427
dial-backup connect-timeout <seconds>
Use the dial-backup connect-timeout command to specify the number of seconds to wait for a connection
after a call is attempted before trying to call again or dialing a different number. It is recommended this
number be greater than 60.
Syntax Description
<seconds>
Selects the amount of time in seconds that the router will wait for a connection
before attempting another call (valid range: 10 to 300)
Default Values
<seconds> 60 seconds
Command Modes
(config-fr 1.16)# Virtual Frame Relay Sub-Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Usage Examples
The following configures the ADTRAN OS to wait 120 seconds before retrying a failed dial-backup call:
(config)#
interface fr 1.16
(config-fr 1.16)#
dial-backup connect-timeout 120