Command Reference Guide Frame Relay Interface Config Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 403
frame-relay lmi-n392dce <threshold>
Use the frame-relay lmi-n392dce command to set the N392 error threshold for the DCE endpoint. Typical
applications should leave the default value for this setting. Use the no form of this command to return to
the default value.
Syntax Description
<threshold>
Sets the threshold value (valid range: 1-10)
Default Values
<threshold> 3 errors
Command Modes
(config-fr 1)# Virtual Frame Relay Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Usage Examples
The following example sets the N392 timer for 5 seconds:
(config)#
interface frame-relay 1
(config-fr 1)#
frame-relay lmi-n392dce 5