Frame Relay Interface Config Command Set Command Reference Guide
408 © 2003 ADTRAN, Inc. 61950860L1-35D
frame-relay lmi-t392dce <seconds>
Use the frame-relay lmi-t392dce command to set the T392 polling verification timer for the DCE
endpoint. Typical applications should leave the default value for this timer. Use the no form of this
command to return to the default value.
Syntax Description
<seconds>
Sets the timer value in seconds (valid range: 5-30)
Default Values
<seconds> 10 seconds
Command Modes
(config-fr 1)# Virtual Frame Relay Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Functional Notes
The T392 sets the timeout (in seconds) between polling intervals. This parameter needs to be a few seconds
longer than the T391 setting of the attached frame relay device.
Usage Examples
The following example sets the T392 timer for 15 seconds:
(config)#
interface frame-relay 1
(config-fr 1)# f
rame-relay lmi-t392dce 15