Command Reference Guide Frame Relay Interface Config Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 401
frame-relay lmi-n391dce <seconds>
Use the frame-relay lmi-n391dce command to set the n391 full status polling counter for the DCE
endpoint. Typical applications should leave the default value for this timer. Use the no form of this
command to return to the default value.
Syntax Description
<seconds>
Sets the timer value in seconds (valid range: 1-255)
Default Values
<seconds> 6 seconds
Command Modes
(config-fr 1)# Virtual Frame Relay Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Functional Notes
The N391 timer determines how many link integrity polls occur in between full status polls.
Usage Examples
The following example sets the N391 timer for 20 seconds:
(config)#
interface frame-relay 1
(config-fr 1)#
frame-relay lmi-n391dce 20