Command Reference Guide Frame Relay Interface Config Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 411
snmp trap link-status
Use the snmp trap link-status command to control the SNMP variable ifLinkUpDownTrapEnable (RFC
2863), which enables (or disables) the interface to send SNMP traps when there is an interface status
change. Use the no form of this command to disable this trap.
Syntax Description
No subcommands
Default Values
By default, the ifLinkUpDownTrapEnable OID is set to enabled for all interfaces except virtual frame relay
interfaces.
Command Modes
(config-interface)# Interface Configuration Mode
Valid interfaces include: Ethernet (eth 0/1), T1 (t1 1/1), DSX-1 (t1 1/2), serial
(ser 1/1), DDS (dds 1/1), virtual frame relay (fr 1), virtual PPP (ppp 1), and SHDSL
(shdsl 1/1).
Command History
Release 1.1 Command was introduced
Functional Notes
The
snmp trap link-status
command is used to control the RFC 2863 ifLinkUpDownTrapEnable OID (OID
number 1.3.6.1.2.1.31.1.1.1.14.0).
Usage Examples
The following example disables the link-status trap on the frame relay interface:
(config)#
interface frame-relay 1
(config-fr 1)#
no snmp trap link-status