Frame Relay Interface Config Command Set Command Reference Guide
404 © 2003 ADTRAN, Inc. 61950860L1-35D
frame-relay lmi-n392dte <threshold>
Use the frame-relay lmi-n392dte command to set the N392 error threshold for the DTE endpoint. Typical
applications should leave the default value for this setting. Use the no form of this command to return to
the default value.
Syntax Description
<threshold>
Sets the threshold value (valid range: 1-10)
Default Values
<threshold> 3 errors
Command Modes
(config-fr 1)# Virtual Frame Relay Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Functional Notes
If the error threshold is met, the signaling state status is changed to down, which indicates a service-affecting
condition. This condition is cleared once N393 consecutive error-free events are received. N392 defines the
number of errors required in a given event window, while N393 defines the number of polling events in each
window.
For example:
If N392=3 and N393=4, then if three errors occur within any four events, the interface is determined inactive.
Usage Examples
The following example sets the N392 threshold for 5 errors:
(config)#
interface frame-relay 1
(config-fr 1)#
frame-relay lmi-n392dte 5