Remote Configuration Smart 16e Shelf User Manual
32 © 2004 ADTRAN, Inc. 64202023L5-1B
Remote Configuration
The Smart 16e Shelf and any rackmount units in the shelf can be configured remotely through the
DTE/DCE EIA 232 port using a modem. See Figure 8. Follow these steps to set up this application.
1. Configure the modem as follows:
Display Result Code
Echo Off
Result Code Displayed as Words (verbose form)
•Normal DTR
•Normal DCD
Auto Answer On
2. At the remote site, configure the EIA232 DIR option as DTE.
3. Make sure the shelf baud rate is not configured above 19.2 kbps.
4. Set the data format as follows: word length = 8 bits, parity = none, stop bit = 1.
Figure 8. Remote Configuration
MODEM
MODEM
D
T
E
/
D
C
E
E
I
A
2
3
2
SMART 16e
AC
POWER I/F
ALARM
NO
COM
NO
COM
F1
F2
#1
#2
5A
250V
3AG
115VAC/60 HZ
2.5 AMP
L
A
N
10 BASE T
FU
SE
FU
SE