ADTRAN Network Router DSU 56 Instrukcja Użytkownika Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 44
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
Chapter 3. Test Modes
3-2 DSU 56/64 User Manual 61200062L1-1
If an E
PROM
C
HECKSUM
failure is detected during self test, CS,
ALM, PTRN, and E
RROR
indicators all flash at the end of the self
test.
NEAR END TESTS
The local DSU 56/64 can perform the following near end tests:
•DTE Only
DTE with Test Pattern
DTE and LOOP (LL)
Loop Only (RT)
DTE ONLY TEST
The DTE O
NLY
test can test both the DTE interface of the local DSU
56/64 plus its loop transmitter and receiver. For this test, the loop
transmit data is connected to the loop receive data at a point close
to the physical network interface.
The loopback point and the signal paths for this test are shown in
Figure 3-1.
Figure 3-1. DTE Only Test Diagram
56/64 DSU
DTE
Receive
Interface
DTE
Transmit
Interface
Loop
Transmit
Interface
Loop
Receive
Interface
DTE
Only
TD
DTE or Test
Equipment
Interface
Network
Interface
RD
Loop TX
Loop RX
Przeglądanie stron 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 43 44

Komentarze do niniejszej Instrukcji

Brak uwag