ADTRAN 1204006L1 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking ADTRAN 1204006L1. ADTRAN 1204006L1 User manual [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 198
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
TSU IQ+
T1 Frame Relay
Performance Monitoring TSU
with V.35 and DSX-1 Ports
User Manual
61200275L1-1C
December 2000
1200275L1 TSU IQ+ Unit
1204005L1 Ethernet Card
1204001L1 4-wire SW56 DBU Card
1204002L1 V.34 DBU Card
1204004L1 BRI ISDN DBU Card
1204006L1 External DCE Card
1204008L1 PRI DBU Card
1204002L2 V.34 DBU Card
Przeglądanie stron 0
1 2 3 4 5 6 ... 197 198

Podsumowanie treści

Strona 1 - User Manual

TSU IQ+T1 Frame RelayPerformance Monitoring TSUwith V.35 and DSX-1 PortsUser Manual61200275L1-1CDecember 20001200275L1 TSU IQ+ Unit1204005L1 Ethernet

Strona 2 - Trademark Information

x TSU IQ+ User Manual 61200275L1-1Canadian Equipment LimitationsNotice: The Canadian Industry and Science Canada label identifies certified equip-ment

Strona 3

Chapter 8. Configuring DBU Options8-4 TSU IQ+ User Manual 61200275L1-1AUTO DBUThe AUTOMATICDBU option specifies whether the unitautomatically enters d

Strona 4 - Service Type REN/SOC FIC USOC

Chapter 8. Configuring DBU Options61200275L1-1 TSU IQ+ User Manual 8-5be identical. If using front panel entry, see the section EnteringLetters Using

Strona 5 - Save These Instructions

Chapter 8. Configuring DBU Options8-6 TSU IQ+ User Manual 61200275L1-1DBU TIMERSFail Timer (FAIL TMR)This option sets the amount of time the dedicated

Strona 6

Chapter 8. Configuring DBU Options61200275L1-1 TSU IQ+ User Manual 8-7DBU CARD CONFIGURATION OPTIONSThefollowingselectionsaredependentuponthetypeofDBU

Strona 7

Chapter 8. Configuring DBU Options8-8 TSU IQ+ User Manual 61200275L1-1B-Channel Bit Rate (B-CH BIT RATE)Select the channel bit rate for the ISDN servi

Strona 8 - Interference Statement

Chapter 8. Configuring DBU Options61200275L1-1 TSU IQ+ User Manual 8-9Physical Layer OptionsThe following sections describe the PHYSICALLAYEROPTIONSav

Strona 9

Chapter 8. Configuring DBU Options8-10 TSU IQ+ User Manual 61200275L1-1Local LoopbackThis forces the PRI into loopback on the network. This option can

Strona 10

61200275L1-1 TSU IQ+ User Manual 9-1Chapter 9System ConfigurationAccess System configuration selections by first choosingCONFIGURATIONfrom theMAINmenu

Strona 11 - LIMITED PRODUCT WARRANTY

Chapter 9. System Configuration9-2 TSU IQ+ User Manual 61200275L1-1Subnet MaskEnter the subnet mask assigned tothe LAN thatthe ethernet cardisattached

Strona 12

Chapter 9. System Configuration61200275L1-1 TSU IQ+ User Manual 9-3Read Community (RD COMMUNITY)Enter the authentication strings used for SNMP managem

Strona 13 - Table of Contents

61200275L1-1 TSU IQ+ User Manual xiLIMITED PRODUCT WARRANTYADTRAN warrants that for five (5) years from the date of shipment to Customer, allproducts

Strona 14

Chapter 9. System Configuration9-4 TSU IQ+ User Manual 61200275L1-1Previous (PREV key on front panel)Edit the previous entry in the Trap Manager Optio

Strona 15

Chapter 9. System Configuration61200275L1-1 TSU IQ+ User Manual 9-5System NameEnter a descriptive name for the unit. This name can help youdistinguish

Strona 16

Chapter 9. System Configuration9-6 TSU IQ+ User Manual 61200275L1-1ENTERING LETTERS USING THE FRONT PANELConfiguring the READ/WRITECOMMUNITYnames requ

Strona 17

61200275L1-1 TSU IQ+ User Manual 10-1Chapter 10StatisticsFor descriptions of the terminal statistics menus, see the followingsection, Viewing Statisti

Strona 18

Chapter 10. Statistics10-2 TSU IQ+ User Manual 61200275L1-1Figure 10-1. View Statistics MenuTerminal Statistics Display OptionsDTE PORT, NETWORKPORT,

Strona 19

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-3To configure the interval time frame, go to the SYSTEMCONFIGURATIONmenu under HISTORYINTERV

Strona 20

Chapter 10. Statistics10-4 TSU IQ+ User Manual 61200275L1-1Hot KeysOnce you have entered one of the statistics menus, hot keys aredisplayed across the

Strona 21

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-5The following sections describe the information given on thestatistics screens.DTE Port Sta

Strona 22

Chapter 10. Statistics10-6 TSU IQ+ User Manual 61200275L1-1Descriptions of the fields shown on the DTE PORTSTATISTICSscreens follow.Leads OnIf a lead

Strona 23

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-7Signal ErrorNumber of signal frames received with PVC signaling protocolviolations.Signal T

Strona 24

xii TSU IQ+ User Manual 61200275L1-1

Strona 25

Chapter 10. Statistics10-8 TSU IQ+ User Manual 61200275L1-1Length ErrorNumber of frames received with fewer than 5 octets or greater than4500 octets.

Strona 26

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-9Network Port StatisticsInformation given is for the network port since the last reset. SeeF

Strona 27 - List of Figures

Chapter 10. Statistics10-10 TSU IQ+ User Manual 61200275L1-1Descriptions of the fields shown on the NETWORKPORTSTATISTICSscreens are shown below.Signa

Strona 28

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-11Maximum Rx ThroughputMaximum throughput sample in the receive direction for the giveninter

Strona 29 - List of Tables

Chapter 10. Statistics10-12 TSU IQ+ User Manual 61200275L1-1Port UA TimeTime in seconds the network port is unavailable for data delivery.This means t

Strona 30

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-13CRC ErrorsNumber offramesreceivedwithCRC violations. This transmissionerror is also reflec

Strona 31 - Introduction

Chapter 10. Statistics10-14 TSU IQ+ User Manual 61200275L1-1Yellow AlarmIf ALARMis displayed, the telco end of the T1 was out of frame synconeormoreti

Strona 32 - Features

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-15UnrouteableNumber offramesreceivedon a dedicated management DLCIwithan IP address that doe

Strona 33 - UNDERSTANDING FRAME RELAY

Chapter 10. Statistics10-16 TSU IQ+ User Manual 61200275L1-1Red AlarmIf ALARMis displayed, aloss of frame synchronization occurred oneor more times du

Strona 34 - Fractional T1

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-17SNA-Peripheral (FID2) without Layer 2 (LLC2)SNA-APPN without Layer 2 (LLC2)SNA-Netbios wit

Strona 35 - SNMP MANAGEMENT

61200275L1-1 TSU IQ+ User Manual xiiiTable of ContentsList of Figures ...

Strona 36 - Ethernet Card

Chapter 10. Statistics10-18 TSU IQ+ User Manual 61200275L1-1Px Type (listed for each interval)The protocol type being examined for the given interval

Strona 37 - DCE Card

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-19Px Tx BytesIn the Network Port view, this is the number of bytes transmittedon the network

Strona 38 - Chapter 1. Introduction

Chapter 10. Statistics10-20 TSU IQ+ User Manual 61200275L1-1Address TypeThe ADDRESSTYPEfield displays IP, indicating that the TOPTALKERSfeature is tra

Strona 39 - Installation

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-21Figure 10-8. DBU Port Statistic (View by Day)PRI ChannelsDS0 Channel identifier (channels

Strona 40 - REAR PANEL

Chapter 10. Statistics10-22 TSU IQ+ User Manual 61200275L1-1PRI StateCurrent state of the PRI Circuit. Possible states are listed in Table10-3.Table 1

Strona 41 - Chapter 2. Installation

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-23Maximum Rx UtilizationMaximum utilization sample in the receive direction for the givenint

Strona 42 - Test Jacks

Chapter 10. Statistics10-24 TSU IQ+ User Manual 61200275L1-1CRC ErrorNumber offramesreceivedwithCRC violations. This transmissionerror is also reflect

Strona 43 - V.35 Connector

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-25Red AlarmIf ALARMis displayed, aloss of frame synchronization occurred oneor more times du

Strona 44

Chapter 10. Statistics10-26 TSU IQ+ User Manual 61200275L1-1Call ManagerThe CALLMANAGERstatistics screen (shown and described inFigure 10-9) only appl

Strona 45 - Operation

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-27DLCI StatisticsAccess specific DLCI statistics by pressingDfrom the NETWORKorLAYER3STATIST

Strona 46 - Chapter 3. Operation

Table of Contentsxiv TSU IQ+ User Manual 61200275L1-1Power Up...

Strona 47

Chapter 10. Statistics10-28 TSU IQ+ User Manual 61200275L1-1Average Rx UtilizationAverage utilization in the receive direction for the given interval.

Strona 48 - Front Panel Operation

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-29Rx BECNNumber of frames received on the network port over the specifiedDLCI with the BECN

Strona 49

Chapter 10. Statistics10-30 TSU IQ+ User Manual 61200275L1-1Minimum Rx FrameSize of smallest frame received across the DLCI.Maximum Rx FrameSize of la

Strona 50

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-31DLCI ListFor a status summary of all available DLCIs, select DLCI LISTfromthe main VIEWSTA

Strona 51 - Local Login Via Telnet

Chapter 10. Statistics10-32 TSU IQ+ User Manual 61200275L1-1System StatisticsThesystemtimeanddate(assetintheSYSTEMCONFIGURATIONmenu) and the software

Strona 52 - Enter to continue…

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-33VIEWING STATISTICAL INFORMATION (FRONT PANELINTERFACE)Select STATSfrom the MAINmenu. From

Strona 53

Chapter 10. Statistics10-34 TSU IQ+ User Manual 61200275L1-1Signal StateCurrent signaling state of DTE port (up or down). See Figure 10-13.Figure 10-1

Strona 54 - 6. You will now see the M

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-35Network Port Statistics Available on Front PanelTSU Loop StateCurrent state of the incomin

Strona 55

Chapter 10. Statistics10-36 TSU IQ+ User Manual 61200275L1-1Port UA TimeTime in seconds the network port is unavailable for data delivery.This can mea

Strona 56

Chapter 10. Statistics61200275L1-1 TSU IQ+ User Manual 10-37Frames InTotal received frames since the unit went into dialbackup mode(orsince last reset

Strona 57 - REMOTE LOGIN

Table of Contents61200275L1-1 TSU IQ+ User Manual xvChapter 4. ApplicationsManagement Applications ...

Strona 58 - NY KEY TO CONTINUE

Chapter 10. Statistics10-38 TSU IQ+ User Manual 61200275L1-1

Strona 59

61200275L1-1 TSU IQ+ User Manual 11-1Chapter 11TestingThis menu allows you to perform diagnostics by initiating pingtests (if the ethernet card is ins

Strona 60 - Main Menu

Chapter 11. Testing11-2 TSU IQ+ User Manual 61200275L1-1Figure 11-2. Front Panel Test MenuPINGS TXPINGS RX1 PING ADDRESS MIN RESP TIME1PING* 2STARTPIN

Strona 61 - Applications

Chapter 11. Testing61200275L1-1 TSU IQ+ User Manual 11-3PingSelect PINGto send a ping request to a specific address. This optionis available only with

Strona 62 - Router Router

Chapter 11. Testing11-4 TSU IQ+ User Manual 61200275L1-1PVC LoopbackA PVC LOOPBACKtest is a non-intrusive loopback option for eachPVC. During this tes

Strona 63 - Out-of-Band Management

Chapter 11. Testing61200275L1-1 TSU IQ+ User Manual 11-5Stop TestEnds the test in progress prematurely or terminates a continuoustest.View TestDisplay

Strona 64

Chapter 11. Testing11-6 TSU IQ+ User Manual 61200275L1-1Average Loop Response Time (AVG RESP TIME)Average round-trip time (in seconds) for the current

Strona 65 - In-Band Management

Chapter 11. Testing61200275L1-1 TSU IQ+ User Manual 11-7DSX LoopbackA DSX LOOPBACKtest allows the user to initiate a loopback test attheDSX-1interface

Strona 66

Chapter 11. Testing11-8 TSU IQ+ User Manual 61200275L1-1

Strona 67

61200275L1-1 TSU IQ+ User Manual 12-1Chapter 12Activating Dialing FunctionsDIALING OPTIONSThe dial options available from the main menu (4=DIAL)forthe

Strona 68 - TSU IQ+ TSU IQ+

Table of Contentsxvi TSU IQ+ User Manual 61200275L1-1DBU Application 2 (PRI)...

Strona 69

Chapter 12. Activating Dialing Functions12-2 TSU IQ+ User Manual 61200275L1-1Figure 12-2. Dial Options Menu (PRI DBU)Dial Options when Dial Backup is

Strona 70 - DIAL BACKUP APPLICATION

Chapter 12. Activating Dialing Functions61200275L1-1 TSU IQ+ User Manual 12-3Dial Options During Dial BackupDial BackupTheTSUIQ+promptsyoutoenteranumb

Strona 71

Chapter 12. Activating Dialing Functions12-4 TSU IQ+ User Manual 61200275L1-1

Strona 72 - DBU Application 1(non-PRI)

61200275L1-1 TSU IQ+ User Manual A-1Appendix APinoutsThe following tables give the pin assignments for the TSU IQ+ andcard connectors. For more inform

Strona 73 - Chapter 4. Applications

Appendix A. PinoutsA-2 TSU IQ+ User Manual 61200275L1-1Table A-3. Pin Assignments for Control ConnectorTable A-4. Pin Assignments for 10BaseT Connecto

Strona 74 - DBU Application 2 (PRI)

Appendix A. Pinouts61200275L1-1 TSU IQ+ User Manual A-3Table A-5. Pin Assignment for V.35 ConnectorPin CCITT DescriptionA 101 Protective ground (PG)B

Strona 75

Appendix A. PinoutsA-4 TSU IQ+ User Manual 61200275L1-1Table A-6. 4-Wire, V.34, and BRI ISDN DBU CardPin AssignmentsTable A-7. Pin Assignments for the

Strona 76

Appendix A. Pinouts61200275L1-1 TSU IQ+ User Manual A-5Table A-8. DTE/DCE Connector Pin Assignments(DCE Card Option)DB25 Pin# V.35 Pin# Function DTEx

Strona 77 - Configuration Overview

Appendix A. PinoutsA-6 TSU IQ+ User Manual 61200275L1-1

Strona 78

61200275L1-1 TSU IQ+ User Manual B-1Appendix BSpecifications SummarySPECIFICATIONS AND FEATURESThis appendix provides the standard specifications and

Strona 79

Table of Contents61200275L1-1 TSU IQ+ User Manual xviiIn-Band Loopback (LOOPBACK)...

Strona 80

Appendix B. Specifications SummaryB-2 TSU IQ+ User Manual 61200275L1-1DSX• RJ-48C, 4-wire• Framing: SF/ESF with auto detection• ESF Format: AT&T 5

Strona 81 - Data Port Configuration

Appendix B. Specifications Summary61200275L1-1 TSU IQ+ User Manual B-3Agency Approvals•FCCPart15,ClassA•FCCPart68• Industry Canada CS03•ULandCULReleva

Strona 82 - PORT MAP

Appendix B. Specifications SummaryB-4 TSU IQ+ User Manual 61200275L1-1

Strona 83

61200275L1-1 TSU IQ+ User Manual C-1Appendix CAcronyms and AbbreviationsACK... acknowledgmentAIS... alarm indication

Strona 84 - Frame Relay Options (FR OPTS)

Appendix C. Acronyms and AbbreviationsC-2 TSU IQ+ User Manual 61200275L1-1CSU ... channel service unitCTS... clear to

Strona 85

Appendix C. Acronyms and Abbreviations61200275L1-1 TSU IQ+ User Manual C-3FSU... framerelayserviceunitFT1... fracti

Strona 86

Appendix C. Acronyms and AbbreviationsC-4 TSU IQ+ User Manual 61200275L1-1PU ... physical unitPVC ... permanent vir

Strona 87 - Configuring the Network Port

Appendix C. Acronyms and Abbreviations61200275L1-1 TSU IQ+ User Manual C-5UAS... unavailable secondsUNI... user-to-ne

Strona 88

Appendix C. Acronyms and AbbreviationsC-6 TSU IQ+ User Manual 61200275L1-1

Strona 89

61200275L1-1 TSU IQ+ User Manual D-1Appendix DGlossaryAISalarm indication signal. A signal transmitted instead of the normal signal tomaintain continu

Strona 90

Table of Contentsxviii TSU IQ+ User Manual 61200275L1-1Chapter 8. Configuring DBU OptionsAuto DBU ...

Strona 91 - Maximum PVC Count

Appendix D. GlossaryD-2 TSU IQ+ User Manual 61200275L1-1bandwidthThe bandwidth determines the rate at which information can be sent through achannel (

Strona 92 - PVC Options (PVC CONFIG)

Appendix D. Glossary61200275L1-1 TSU IQ+ User Manual D-3bridgeA device that supports LAN-to-LAN communications. Bridges may beequipped to provide fram

Strona 93

Appendix D. GlossaryD-4 TSU IQ+ User Manual 61200275L1-1clockingAn oscillator-generated signal that provides a timing reference for a transmis-sion li

Strona 94

Appendix D. Glossary61200275L1-1 TSU IQ+ User Manual D-5CTSclear to send. A signal on the DTE interface indicating that the DCE is clear tosend data.C

Strona 95

Appendix D. GlossaryD-6 TSU IQ+ User Manual 61200275L1-1DLCIdata linkconnectionidentifier. A unique numberassigned to a PVC end pointina frame relay n

Strona 96

Appendix D. Glossary61200275L1-1 TSU IQ+ User Manual D-7far endThe unit or units not on-site (at the customer's premises or the other end of theT

Strona 97 - Configuring DBU Options

Appendix D. GlossaryD-8 TSU IQ+ User Manual 61200275L1-1framingA control procedure used with multiplexed digital channels (such as T1carriers)where bi

Strona 98

Appendix D. Glossary61200275L1-1 TSU IQ+ User Manual D-9ISDNintegrated services digital network. A network architecture that enables end-to-end digita

Strona 99

Appendix D. GlossaryD-10 TSU IQ+ User Manual 61200275L1-1near endThe unit on-site.network interface (NI)The point of interconnection between the TSU I

Strona 100 - DBU OPTIONS

Appendix D. Glossary61200275L1-1 TSU IQ+ User Manual D-11point-to-pointType of communications link that connects a single device to another singledevi

Strona 101 - DBU CRITERIA

Table of Contents61200275L1-1 TSU IQ+ User Manual xixLocal Loopback ...

Strona 102 - DBU TIMERS

Appendix D. GlossaryD-12 TSU IQ+ User Manual 61200275L1-1serviceThe provision oftelecommunications to customers by a common carrier, admin-istration,

Strona 103 - ISDN Options

Appendix D. Glossary61200275L1-1 TSU IQ+ User Manual D-13synchronizing bits (sync bits)A fixed pattern in synchronous transmission used to identify th

Strona 104 - PRI Options

Appendix D. GlossaryD-14 TSU IQ+ User Manual 61200275L1-1

Strona 105

61200275L1-1 TSU IQ+ User Manual Index-1IndexNumerics10BaseT connector, pinout A-24-wire SW56 DBU card, description, 1-74-wire, pinout A-4Aactivating

Strona 106 - DCE Options

IndexIndex-2 TSU IQ+ User Manual 61200275L1-1DTE rates, B-1DTE/DCE connector, pinout A-5Eethernet card, description, 1-6FFCC radio frequency interfere

Strona 107 - System Configuration

Index61200275L1-1 TSU IQ+ User Manual Index-3return material authorization (RMA) vSSafety Instructions vsignaling formats 7-1SNMP, general description

Strona 108 - IP Address (IP ADDRESS)

IndexIndex-4 TSU IQ+ User Manual 61200275L1-1

Strona 109 - Read Community (RD COMMUNITY)

Product Support InformationPre-Sales Inquiries and Applications SupportPlease contact your local distributor, ADTRAN Applications Engineering, orADTRA

Strona 111 - System Time/Date

Trademark InformationOpenView is a registered trademark of Hewlett-Packard Company.SunNet Manager is a registered trademark of Sun Microsystems, Inc.N

Strona 112

Table of Contentsxx TSU IQ+ User Manual 61200275L1-1DTE Port Statistics...

Strona 113 - Statistics

Table of Contents61200275L1-1 TSU IQ+ User Manual xxiMaximum Tx Utilization ...

Strona 114

Table of Contentsxxii TSU IQ+ User Manual 61200275L1-1Path Code ...

Strona 115

Table of Contents61200275L1-1 TSU IQ+ User Manual xxiiiT1 UA Time ...

Strona 116 - Hot Keys

Table of Contentsxxiv TSU IQ+ User Manual 61200275L1-1Tx Burst Seconds ...

Strona 117 - DTE Port Statistics

Table of Contents61200275L1-1 TSU IQ+ User Manual xxvPath Code ...

Strona 118

Table of Contentsxxvi TSU IQ+ User Manual 61200275L1-1Average Loop Response Time (AVG RESP TIME) ...11-6Reset Test Stats

Strona 119

61200275L1-1 TSU IQ+ User Manual xxviiList of FiguresFigure 2-1. TSU IQ+ Rear View...

Strona 120 - Chapter 10. Statistics

List of Figuresxxviii TSU IQ+ User Manual 61200275L1-1Figure 8-1. DBU Options Menu (with ISDN DBU Card)...8-1

Strona 121 - Network Port Statistics

61200275L1-1 TSU IQ+ User Manual xxixList of TablesTable 4-1. Example Settings for Dial Backup Options...4

Strona 122

61200275L1-1 TSU IQ+ User Manual iiiThe following conventions are used in this manual.Notes provide additional useful information.Cautions signify inf

Strona 123

List of Tablesxxx TSU IQ+ User Manual 61200275L1-1

Strona 124

61200275L1-1 TSU IQ+ User Manual 1-1Chapter 1IntroductionPRODUCT OVERVIEWThe ADTRAN TSU IQ+ provides the visibility and control neededfor both the phy

Strona 125

Chapter 1. Introduction1-2 TSU IQ+ User Manual 61200275L1-1FeaturesFeatures of the TSU IQ+ are:• Complete and comprehensive frame relay monitoring,inc

Strona 126

Chapter 1. Introduction61200275L1-1 TSU IQ+ User Manual 1-3UNDERSTANDING FRAME RELAYFrame relay is a wide area network (WAN) service designed tominimi

Strona 127 - DSX Port Statistics

Chapter 1. Introduction1-4 TSU IQ+ User Manual 61200275L1-1T1/FT1 OVERVIEWThe telephone companies (telcos) have used T1 digitalcommunications links fo

Strona 128 - Layer 3 Statistics

Chapter 1. Introduction61200275L1-1 TSU IQ+ User Manual 1-5FT1 remains almost exclusively an inter-exchange carrier (IXC)service. Local exchange carri

Strona 129 - ONFIGURATION

Chapter 1. Introduction1-6 TSU IQ+ User Manual 61200275L1-1TELNETTelnet provides a password-protected, remote login facility to theTSU IQ+. Telnet all

Strona 130

Chapter 1. Introduction61200275L1-1 TSU IQ+ User Manual 1-74-Wire Switched 56 DBU CardThis dial-up 4-wire SW56 card allows you to pay for dataconnecti

Strona 131 - Top Talkers

Chapter 1. Introduction1-8 TSU IQ+ User Manual 61200275L1-1

Strona 132 - DBU Port Statistics

61200275L1-1 TSU IQ+ User Manual 2-1Chapter 2InstallationUNPACK, INSPECT, POWER UPReceipt InspectionCarefully inspectthe TSU IQ+ for any shipping dama

Strona 133

iv TSU IQ+ User Manual 61200275L1-1FCC regulations require that the following information be provided in this manual:1. This equipment complies with P

Strona 134

Chapter 2. Installation2-2 TSU IQ+ User Manual 61200275L1-1The following items are included in ADTRAN shipments of DBUcards:•DBUcard• An 8-position mo

Strona 135

Chapter 2. Installation61200275L1-1 TSU IQ+ User Manual 2-3listed in Pinouts on page A-1. The TSU IQ+ rear panel is shown inFigure 2-1 with optional D

Strona 136

Chapter 2. Installation2-4 TSU IQ+ User Manual 61200275L1-1DBU and LAN Card SlotsThe TSU IQ+ rear panel has two card slots (labeledDBU InterfaceandLAN

Strona 137

Chapter 2. Installation61200275L1-1 TSU IQ+ User Manual 2-5DSX-1 PortTheDSX-1interface provides ashort haul T1connection toa PBX orother customer prem

Strona 138 - Call Manager

Chapter 2. Installation2-6 TSU IQ+ User Manual 61200275L1-1

Strona 139 - DLCI Statistics

61200275L1-1 TSU IQ+ User Manual 3-1Chapter 3OperationFRONT PANELThe TSU IQ+ faceplate is shown in Figure 3-1. Descriptions of eachpart of the front p

Strona 140

Chapter 3. Operation3-2 TSU IQ+ User Manual 61200275L1-1LCD WindowDisplays menu items and messages in this 2 line by 16 characterdisplay.Enter KeySele

Strona 141

Chapter 3. Operation61200275L1-1 TSU IQ+ User Manual 3-3Shift KeyEnter alpha characters by first pressing and releasing theShiftkeyand then pressing t

Strona 142

Chapter 3. Operation3-4 TSU IQ+ User Manual 61200275L1-1TST: TestThis LED is active when the network interface is in a loopbackcondition triggered fro

Strona 143 - DLCI List

Chapter 3. Operation61200275L1-1 TSU IQ+ User Manual 3-5VT-100 Terminal Connection and OperationTo control the TSU IQ+ using a VT-100 terminal, follow

Strona 144 - System Statistics

61200275L1-1 TSU IQ+ User Manual vImportant Safety InstructionsSave These InstructionsWhen using your telephone equipment, please follow these basic s

Strona 145 - INTERFACE)

Chapter 3. Operation3-6 TSU IQ+ User Manual 61200275L1-1IFigure 3-3. Terminal Login MenuFigure 3-4. Terminal Main MenuIn the upper right-hand corner o

Strona 146 - SIGNAL STATE

Chapter 3. Operation61200275L1-1 TSU IQ+ User Manual 3-7TELNETLocal Login Via TelnetBefore you begin, please note the following:Figure 3-5. PC Connect

Strona 147

Chapter 3. Operation3-8 TSU IQ+ User Manual 61200275L1-1To connect to the TSU IQ+ viaTelnet, follow these steps:1. Before attempting to connect via Te

Strona 148

Chapter 3. Operation61200275L1-1 TSU IQ+ User Manual 3-93. Press the Enter key. Then you will see the following screen(Figure 3-8).Figure 3-7. Telnet

Strona 149 - VER 2.200 17AB

Chapter 3. Operation3-10 TSU IQ+ User Manual 61200275L1-16. You will now see the MAINmenu of the unit (Figure 3-8).Figure 3-8. Local Main Menu Screen7

Strona 150

Chapter 3. Operation61200275L1-1 TSU IQ+ User Manual 3-11Remote Login Via TELNETRemoteLoginviaTelnetisdefinedas telnettingfromthePC into IQ#1 and then

Strona 151 - Chapter 11

Chapter 3. Operation3-12 TSU IQ+ User Manual 61200275L1-13. Press ENTER. Next, you will see the following screen (Figure3-10).Figure 3-10. Telnet Logi

Strona 152 - *with Ethernet Card Installed

Chapter 3. Operation61200275L1-1 TSU IQ+ User Manual 3-13Next, you will see the following screen (Figure 3-11).Figure 3-11. Remote Login Screen5. At t

Strona 153 - Chapter 11. Testing

Chapter 3. Operation3-14 TSU IQ+ User Manual 61200275L1-1Next, you will see the following screen (Figure 3-12).Figure 3-12. Continue or Exit Screen7.

Strona 154 - PVC Loopback

Chapter 3. Operation61200275L1-1 TSU IQ+ User Manual 3-15Yo u w il l n ow s ee t he MAINmenu of the remote unit(Figure 3-13).Figure 3-13. Remote Main

Strona 155

vi TSU IQ+ User Manual 61200275L1-1Affidavit for Connection of Customer Premises Equipment to 1.544MBPS and/or Subrate Digital ServicesFor the work to

Strona 156 - TATISTICS

Chapter 3. Operation3-16 TSU IQ+ User Manual 61200275L1-1TSU IQ+ MENU STRUCTUREThe opening menu is the access point to all other operations. TheMAINme

Strona 157 - DSX Loopback

61200275L1-1 TSU IQ+ User Manual 4-1Chapter 4ApplicationsThis chapter provides examples of some common TSU IQ+management options as well as an example

Strona 158

Chapter 4. Applications4-2 TSU IQ+ User Manual 61200275L1-1fully accessible for configuration, diagnostics, and statisticsviewing. Figure 4-1 shows an

Strona 159 - Activating Dialing Functions

Chapter 4. Applications61200275L1-1 TSU IQ+ User Manual 4-3Out-of-Band ManagementThis management option (shown in Figure 4-2) is commonly usedin situa

Strona 160

Chapter 4. Applications4-4 TSU IQ+ User Manual 61200275L1-1Minimum Configuration RequirementsThe following options (all found in the SYSTEMportion of

Strona 161

Chapter 4. Applications61200275L1-1 TSU IQ+ User Manual 4-5Trap Manager IP AddressEnter the IP address of the SNMP manager to which the TSU IQ+sends t

Strona 162

Chapter 4. Applications4-6 TSU IQ+ User Manual 61200275L1-1Local PVC management can be used at any location that has arouter. Therefore, remote sites

Strona 163 - Appendix A

Chapter 4. Applications61200275L1-1 TSU IQ+ User Manual 4-7Write CommunitySet the WRITECOMMUNITYname to match the NMS settings.Trap Manager DLCIIdenti

Strona 164 - Appendix A. Pinouts

Chapter 4. Applications4-8 TSU IQ+ User Manual 61200275L1-1Figure 4-4. Shared PVC Management ApplicationMinimum Configuration RequirementsThe followin

Strona 165

Chapter 4. Applications61200275L1-1 TSU IQ+ User Manual 4-9The next five settings are applicable for SNMP access only.Read CommunitySet the READCOMMUN

Strona 166

61200275L1-1 TSU IQ+ User Manual viitraining materials and instructions provided by the manufacturer/grantee of theequipment used to encode analog sig

Strona 167

Chapter 4. Applications4-10 TSU IQ+ User Manual 61200275L1-1Figure 4-5. Dedicated PVC Management ApplicationMinimum Configuration RequirementsThe conf

Strona 168

Chapter 4. Applications61200275L1-1 TSU IQ+ User Manual 4-11ATSU IQ+with multiple PVCsto multiple sites canalsooriginateacalltoone siteduringan outage

Strona 169 - Specifications Summary

Chapter 4. Applications4-12 TSU IQ+ User Manual 61200275L1-1DBU Application 1(non-PRI)The following application shows the critical configuration requi

Strona 170

Chapter 4. Applications61200275L1-1 TSU IQ+ User Manual 4-13Table 4-1. Example Settings for Dial Backup OptionsTable 4-2. Example Settings for PVC Con

Strona 171

Chapter 4. Applications4-14 TSU IQ+ User Manual 61200275L1-1DBU Application 2 (PRI)The following application shows the critical configuration for acas

Strona 172

Chapter 4. Applications61200275L1-1 TSU IQ+ User Manual 4-15Table 4-3. Example Settings for PRI DBU Card (A)Table 4-4. Global DBU Settings (B and C)Ta

Strona 173 - Acronyms and Abbreviations

Chapter 4. Applications4-16 TSU IQ+ User Manual 61200275L1-1

Strona 174

61200275L1-1 TSU IQ+ User Manual 5-1Chapter 5Configuration OverviewLOCAL AND REMOTE CONFIGURATIONThe TSU IQ+ can be configured locally or communicatio

Strona 175

Chapter 5. Configuration Overview5-2 TSU IQ+ User Manual 61200275L1-1CONFIGURATIONmenutreesareshowninFigure5-2onpage5-3fortheterminal and Figure 5-3 o

Strona 176

Chapter 5. Configuration Overview61200275L1-1 TSU IQ+ User Manual 5-3Figure 5-2. Terminal Configuration Tree1 DSX1 1 None1PORT MAP DS0s 1-24 2 Nx 1 Fl

Strona 177

viii TSU IQ+ User Manual 61200275L1-1Affidavit Requirements for Connection to Digital Services• An affidavit is required to be given to the telephone

Strona 178

Chapter 5. Configuration Overview5-4 TSU IQ+ User Manual 61200275L1-1Figure 5-3. Front Panel Configuration Tree1 DSX1 1 None1 PORT MAP DS0s 1-24 2 Nx

Strona 179 - Glossary

61200275L1-1 TSU IQ+ User Manual 6-1Chapter 6Data Port ConfigurationUse the DATAPORTCONFIGURATIONmenu to create a port map andto configure the V.35 Nx

Strona 180 - Appendix D. Glossary

Chapter 6. Data Port Configuration6-2 TSU IQ+ User Manual 61200275L1-1PORT MAPThe PORTMAPdesignates which DS0s are assigned to which port.For example,

Strona 181

Chapter 6. Data Port Configuration61200275L1-1 TSU IQ+ User Manual 6-3Follow RTSThe CTS lead is on when the RTS lead is on (and off when the RTSlead i

Strona 182

Chapter 6. Data Port Configuration6-4 TSU IQ+ User Manual 61200275L1-1Frame Relay Options (FR OPTS)The frame relay protocol is a synchronous protocol

Strona 183

Chapter 6. Data Port Configuration61200275L1-1 TSU IQ+ User Manual 6-5Management DLCI (MGMT DLCI)To use local PVC management, enter the management dat

Strona 184

Chapter 6. Data Port Configuration6-6 TSU IQ+ User Manual 61200275L1-1DSX PORTConfigure these options to be compatible with the T1 serviceprovided and

Strona 185

61200275L1-1 TSU IQ+ User Manual 7-1Chapter 7Configuring the Network PortNETWORK PORTAccess the NETWORKPORTmenus by selecting NETWORKPORTfrom the CONF

Strona 186

Chapter 7. Configuring the Network Port7-2 TSU IQ+ User Manual 61200275L1-1Figure 7-1. Terminal Network Port Configuration MenuPhysical Layer Options

Strona 187

Chapter 7. Configuring the Network Port61200275L1-1 TSU IQ+ User Manual 7-3Clock Source (CLK SOURCE)Select the clock source to be derived from the net

Strona 188

61200275L1-1 TSU IQ+ User Manual ixCanadian Emissions RequirementsThis digital apparatus does not exceed the Class A limits for radio noise emissionsf

Strona 189

Chapter 7. Configuring the Network Port7-4 TSU IQ+ User Manual 61200275L1-1Frame Relay Options (FR OPTS)The following selections areavailable when FRA

Strona 190

Chapter 7. Configuring the Network Port61200275L1-1 TSU IQ+ User Manual 7-5The status of the connection can be viewed in the STATISTICSmenuunder NETWO

Strona 191

Chapter 7. Configuring the Network Port7-6 TSU IQ+ User Manual 61200275L1-1History Interval Count (HIST INT COUNT)Set the number of history intervals

Strona 192

Chapter 7. Configuring the Network Port61200275L1-1 TSU IQ+ User Manual 7-7equipped with an “Adtran Safety Net” device that is capable ofrestoring the

Strona 193 - Numerics

Chapter 7. Configuring the Network Port7-8 TSU IQ+ User Manual 61200275L1-1packets. Lost packet counts are given in the STATISTICSmenus.Choices: DISAB

Strona 194

Chapter 7. Configuring the Network Port61200275L1-1 TSU IQ+ User Manual 7-9Next (NEXT key on front panel)Edit the next entry in the PVC OPTIONStable.P

Strona 195

Chapter 7. Configuring the Network Port7-10 TSU IQ+ User Manual 61200275L1-1

Strona 196

61200275L1-1 TSU IQ+ User Manual 8-1Chapter 8Configuring DBU OptionsThe DIALBACKUPCONFIGURATIONmenu (Figure 8-1) is availableonly whenan optional DBU

Strona 197 - Product Support Information

Chapter 8. Configuring DBU Options8-2 TSU IQ+ User Manual 61200275L1-1Figure 8-2. Dial Backup Menu Tree1 DISABLE1 AUTO DBU 2 ENABLE1 DISABLE1ANSWERALW

Strona 198

Chapter 8. Configuring DBU Options61200275L1-1 TSU IQ+ User Manual 8-3Figure 8-3. Dial Backup MenuTree with Option Cards InstalledWith V.34 DBU option

Komentarze do niniejszej Instrukcji

Brak uwag