MX2810
M13 Multiplexer
User Manual
Manual P/N 61185001L1-1C
CD P/N 32536153@A
61185001L1-1C
April 2003
4185001L1 MX2810 Chassis with two PSUs and two DS3 Controllers
4185001L2 MX2810 Chassis with two PSUs and one DS3 Controller
4185001L3 MX2810 Chassis with one PSU and two DS3 Controllers
4185001L4 MX2810 Chassis with one PSU and one DS3 Controller
1200287L1 Amp to Punch-Down Cable 25 ft.
1200287L5 Amp to Punch-Down Cable 50 ft.
1200287L7 Amp to Punch-Down Cable 100 ft.
1200291L1 Breakout Panel
1200291L5 BNC Patch Panel
Przeglądanie stron 0
1 2 3 4 5 6 ... 203 204

Podsumowanie treści

Strona 1 - User Manual

MX2810M13 Multiplexer User ManualManual P/N 61185001L1-1CCD P/N 32536153@A61185001L1-1CApril 20034185001L1 MX2810 Chassis with two PSUs and two DS3 Co

Strona 2 - Trademark Information

Table of Contentsx MX2810 M13 User Manual 61185001L1-1DS2 Statistics...

Strona 3 - Service Type REN FIC USOC

Chapter 6. Loopbacks6-4 MX2810 M13 User Manual 61185001L1-1Figure 6-5. Digital Line/Network LoopbackCodec Line/NetA CODEC LINE/NET loopback performs

Strona 4

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-5CSU LoopbackA CSU LOOPBACK enables the MX2810 to generate a CSU loop up pattern (001001…) t

Strona 5

Chapter 6. Loopbacks6-6 MX2810 M13 User Manual 61185001L1-1Figure 6-7. Loopback Menu with BERT SelectedLine BERTA LINE BERT enables the MX2810 to per

Strona 6 - Warranty and Customer Service

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-7DS3 LOOPBACKSAfter you select DS3 LOOPBACK, the menu in Figure 6-8 appears. The sections fo

Strona 7

Chapter 6. Loopbacks6-8 MX2810 M13 User Manual 61185001L1-1Figure 6-9. Line Loopback TestDigital LoopbackA DIGITAL LOOPBACK loops the entire DS3 back

Strona 8

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-9Figure 6-11. Network Loopback TestRemote LoopbackA REMOTE LOOPBACK performs a loopback on

Strona 9

Chapter 6. Loopbacks6-10 MX2810 M13 User Manual 61185001L1-1Figure 6-12. DS2 Loopback MenuDS2 NetworkA DS2 NETWORK loopback test loops the selected D

Strona 10 - Table of Contents

61185001L1-1 MX2810 M13 User Manual 7-1Chapter 7Circuit RedundancyThe MX2810 provides backup measures of protection for circuit failure. The followin

Strona 11

Chapter 7. Circuit Redundancy7-2 MX2810 M13 User Manual 61185001L1-1NON-REDUNDANT MODEIn Non-Redundant Mode, the MX2810 houses only one controller car

Strona 12

Chapter 7. Circuit Redundancy61185001L1-1 MX2810 M13 User Manual 7-3CIRCUIT FAILURE RECOVERY MODEIn Circuit Failure Recovery Mode, two controller card

Strona 13 - List of Figures

Table of Contents61185001L1-1 MX2810 M13 User Manual xiTL1 Messages ...

Strona 14

Chapter 7. Circuit Redundancy7-4 MX2810 M13 User Manual 61185001L1-1Table 7-1. Configuration Requirements for Circuit RecoverySelection Path Recommen

Strona 15 - List of Tables

61185001L1-1 MX2810 M13 User Manual 8-1Chapter 8Power Loss RecoveryThe MX2810 provides backup measures of protection for both power supply and power s

Strona 16

Chapter 8. Power Loss Recovery8-2 MX2810 M13 User Manual 61185001L1-1NON-REDUNDANT POWER MODEIn Non-Redundant Power Mode, the MX2810 houses only one p

Strona 17 - Introduction

Chapter 8. Power Loss Recovery61185001L1-1 MX2810 M13 User Manual 8-3POWER SUPPLY RECOVERY MODEIn Power Supply Recovery Mode, two power supply cards a

Strona 18 - T3 OVERVIEW

Chapter 8. Power Loss Recovery8-4 MX2810 M13 User Manual 61185001L1-1POWER SUPPLY AND SOURCE RECOVERY MODEIn this mode, two power supply cards are ins

Strona 19 - Chapter 1. Introduction

Chapter 8. Power Loss Recovery61185001L1-1 MX2810 M13 User Manual 8-5BATTERY BACKUP MODEWith the installation of the ADTRAN Power Supply/Battery Charg

Strona 20 - AVAILABLE OPTIONS

Chapter 8. Power Loss Recovery8-6 MX2810 M13 User Manual 61185001L1-1

Strona 21

61185001L1-1 MX2810 M13 User Manual 9-1Chapter 9Transaction Language 1 (TL1)INTRODUCTIONTransaction Language 1 (TL1) is a BELLCORE standard used in th

Strona 22

Chapter 9. Transaction Language 1 (TL1)9-2 MX2810 M13 User Manual 61185001L1-1• 1-way in or 2-way operation•Up to four SVCs• Up to 64 Kbps (synchronou

Strona 23 - Installation and Operation

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-3An account may be setup via the VT100 menus (Configuration/System Manage

Strona 24 - Power Up

Table of Contentsxii MX2810 M13 User Manual 61185001L1-1

Strona 25 - Power Requirements

Chapter 9. Transaction Language 1 (TL1)9-4 MX2810 M13 User Manual 61185001L1-1To bring up a TL1 TELNET connection (up to eight may be active,) a TELNE

Strona 26

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-5<ctag> is the Correlation Tag, a 1 to 6 character alphanumeric ide

Strona 27 - Connecting the Breakout Panel

Chapter 9. Transaction Language 1 (TL1)9-6 MX2810 M13 User Manual 61185001L1-1Acknowledgment MessagesAcknowledgment messages are brief output messages

Strona 28 - Front View

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-7<date> is the date in the form YY-MM-DD,<time> is the time i

Strona 29

Chapter 9. Transaction Language 1 (TL1)9-8 MX2810 M13 User Manual 61185001L1-1The MX2810 specifically uses “quoted line(s)” in the response message of

Strona 30 - Power Connection

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-9Possible values for the ALARM CODE field include:• *C - Critical Alarm•*

Strona 31 - LED Descriptions

Chapter 9. Transaction Language 1 (TL1)9-10 MX2810 M13 User Manual 61185001L1-1the time in HH-MM-SS format, and whether the alarm is NEND of FEND (&qu

Strona 32

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-11For possible CONDTYPE codes for both REPT-ALM and REPT-EVT quoted lines

Strona 33

Chapter 9. Transaction Language 1 (TL1)9-12 MX2810 M13 User Manual 61185001L1-1MOD2 Specifies what entity type to allow:EQPT... General Equipment Unit

Strona 34

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-13TID* Target IDAID UsernameCTAG* Transaction Number (integer)PARAM1 User

Strona 35 - Craft Port

61185001L1-1 MX2810 M13 User Manual xiiiList of FiguresFigure 1-1. E1 Patch Panel...

Strona 36

Chapter 9. Transaction Language 1 (TL1)9-14 MX2810 M13 User Manual 61185001L1-1RTRV-HDR;Description Replies with a normal "COMPLD" responseT

Strona 37

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-15AID* Identifies the component to which the desired alarm pertains. Iden

Strona 38

Chapter 9. Transaction Language 1 (TL1)9-16 MX2810 M13 User Manual 61185001L1-1RTRV-COND-{EQPT|rr|ALL};Description Retrieves the requested alarms and

Strona 39 - Configuration

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-17TL1 Autonomous MessagesAutonomous messages provide a mechanism for real

Strona 40 - Chapter 3. Configuration

Chapter 9. Transaction Language 1 (TL1)9-18 MX2810 M13 User Manual 61185001L1-1An example of this command that would enable "all" autonomous

Strona 41 - DS3 Configuration

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-19;Where "Unit 1" is the <tid> defined in the menus,"

Strona 42

Chapter 9. Transaction Language 1 (TL1)9-20 MX2810 M13 User Manual 61185001L1-1REPT ALMT3301 MN TSA SA NEND DS3 In-test301 MN EXT-DS3 SA FENDFEND DS3

Strona 43 - DS2 Configuration

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-21REPT ALMT3302 (Ctrl A) CR LOS SA NEND DS3 Loss Of Signal303 (Ctrl B)302

Strona 44 - T1/E1 State

Chapter 9. Transaction Language 1 (TL1)9-22 MX2810 M13 User Manual 61185001L1-1REPT-EVT indicates an informational event. Table 9-5 lists possible aut

Strona 45

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-23TL1 ERROR CODESWhen the MX2810 denies a received TL1 command, the Outpu

Strona 46 - T1/E1 Line Length

List of Figuresxiv MX2810 M13 User Manual 61185001L1-1Figure 5-4. DS3 24-Hour Alarm History Screen...

Strona 47 - T1/E1 Loopback Detection

Chapter 9. Transaction Language 1 (TL1)9-24 MX2810 M13 User Manual 61185001L1-1• <keyword> is one of the entries from the following data diction

Strona 48 - T1/E1 Line Identification

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-25TL1 RTRV examples:RTRV-T1::100:1; (this would return all common parame

Strona 49 - XCV Threshold

Chapter 9. Transaction Language 1 (TL1)9-26 MX2810 M13 User Manual 61185001L1-1 Table 9-7. TL1 Editing Data Dictionary for DS3Keyword Type Domain Des

Strona 50 - Management Options

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-27DS3MAXNUMSW INT 0, 1, 2, ..., N Maximum number of times per hour the un

Strona 51 - Alarm Relays

Chapter 9. Transaction Language 1 (TL1)9-28 MX2810 M13 User Manual 61185001L1-1The following data dictionary (Table 9-8) contains entries that are use

Strona 52

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-29The following data dictionary (Table 9-9) contains entries that are use

Strona 53

Chapter 9. Transaction Language 1 (TL1)9-30 MX2810 M13 User Manual 61185001L1-1Table 9-9. TL1 Editing Data Dictionary for DS1Keyword Type Domain Desc

Strona 54 - SNMP Management Options

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-31DSXLBKDETECTION ENUM One of the following:• DISABLE•CSU•NIU• UNAVAILIde

Strona 55

Chapter 9. Transaction Language 1 (TL1)9-32 MX2810 M13 User Manual 61185001L1-1The following data dictionary (Table 9-10) contains entries that are us

Strona 56

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-33PSPOWERFAILRLY Y/N Y or [N] Identifies status of Power Supply Power Fai

Strona 57

61185001L1-1 MX2810 M13 User Manual xvList of Tables Table 2-1. DC Connector Symbol Definitions...

Strona 58

Chapter 9. Transaction Language 1 (TL1)9-34 MX2810 M13 User Manual 61185001L1-1TL1 Loopback Commands:The OPR-LPBK and RLS-LPBK commands are provided a

Strona 59 - System Security

Chapter 9. Transaction Language 1 (TL1)61185001L1-1 MX2810 M13 User Manual 9-35Table 9-12. DS2 TL1 Loopback CommandsThe following table will describe

Strona 60

Chapter 9. Transaction Language 1 (TL1)9-36 MX2810 M13 User Manual 61185001L1-1

Strona 61

61185001L1-1 MX2810 M13 User Manual A-1Appendix AAcceptance Test ProcedureOVERVIEWThis document describes the procedures to be used in performing acce

Strona 62

Appendix A. Acceptance Test ProcedureA-2 MX2810 M13 User Manual 61185001L1-1• Alarm Verification• Redundancy/Protection Switching Tests• Configuring t

Strona 63 - Date & Time

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-3accepted, the MX2810 Main Menu should appear. This is the screen from whi

Strona 64

Appendix A. Acceptance Test ProcedureA-4 MX2810 M13 User Manual 61185001L1-1Miscellaneous• Loopback Time Out = 1 hr. (default) DS2 Configuration (no c

Strona 65 - ONFIGURATION

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-5menu and proceed to the next step. If not, perform the Set Multiple routi

Strona 66

Appendix A. Acceptance Test ProcedureA-6 MX2810 M13 User Manual 61185001L1-1OVERALL SYSTEM AND CABLING TESTNow that the system has been properly provi

Strona 67 - UTILITIES

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-75. The MX2810 will be in an alarm condition because of the previously tes

Strona 68 - Updating Software

List of Tablesxvi MX2810 M13 User Manual 61185001L1-1

Strona 69

Appendix A. Acceptance Test ProcedureA-8 MX2810 M13 User Manual 61185001L1-17. Leave this test set-up in place, as it will be used during the redunda

Strona 70

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-9ALARM VERIFICATIONThe MX2810 has three sets of alarm relay contacts availa

Strona 71 - Utilities

Appendix A. Acceptance Test ProcedureA-10 MX2810 M13 User Manual 61185001L1-1MAJOR and MINOR Alarm Relay TestThis test will actuate the MAJOR and MINO

Strona 72

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-11Power Supply RedundancyWhen installed, the MX2810 can be wired to have ei

Strona 73 - Resetting the System

Appendix A. Acceptance Test ProcedureA-12 MX2810 M13 User Manual 61185001L1-12. Go to the fuse panel at the top of the bay and remove the fuse corres

Strona 74

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-13the Controller, an alarm is initiated and the front panel LEDs reflect th

Strona 75 - Rx Framing

Appendix A. Acceptance Test ProcedureA-14 MX2810 M13 User Manual 61185001L1-12. From the System Management Configuration screen, select Local IP Addr

Strona 76 - Chapter 4. Status

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-15no settings on the MX2810. The RS232 Data Communication Interface on the

Strona 77

Appendix A. Acceptance Test ProcedureA-16 MX2810 M13 User Manual 61185001L1-1• Disabled – No signal continuity exists through the MX2810 and no alarms

Strona 78 - POWER SUPPLY STATE

Appendix A. Acceptance Test Procedure61185001L1-1 MX2810 M13 User Manual A-17MX2810 ATP CHECKLIST/SIGN-OFFUse the table below to identify the MX2810 c

Strona 79 - SYSTEM STATE

61185001L1-1 MX2810 M13 User Manual 1-1Chapter 1IntroductionPRODUCT OVERVIEWThe MX2810 is an M13 multiplexer that consolidates T1 and E1 signals into

Strona 80 - Protection

Appendix A. Acceptance Test ProcedureA-18 MX2810 M13 User Manual 61185001L1-1

Strona 81 - T1/E1 STATE

61185001L1-1 MX2810 M13 User Manual B-1Appendix BPinoutsThe following tables give the pin assignments for the connectors located on the MX2810. For mo

Strona 82 - ACKNOWLEDGE ALARMS (ACO)

Appendix B. PinoutsB-2 MX2810 M13 User Manual 61185001L1-1Table B-2. LAN Port Pin AssignmentsPin Name Description1 TD+ The positive signal for the TD

Strona 83 - Statistics

Appendix B. Pinouts61185001L1-1 MX2810 M13 User Manual B-3Table B-3. Amp Pin AssignmentsPin Function Pin1 RING 1 TIP 1 332 RING 2 TIP 2 343 RING 3 TI

Strona 84 - DS3 Statistics

Appendix B. PinoutsB-4 MX2810 M13 User Manual 61185001L1-1

Strona 85 - Chapter 5. Statistics

61185001L1-1 MX2810 M13 User Manual C-1Appendix CSpecifications SummarySPECIFICATIONS AND FEATURESThis section describes the standard specifications a

Strona 86

Appendix C. Specifications SummaryC-2 MX2810 M13 User Manual 61185001L1-1Line loopbacksDS2 InterfacesDS2 network loopbacksDSX-1 InterfacesLocal and ne

Strona 87

Appendix C. Specifications Summary61185001L1-1 MX2810 M13 User Manual C-3EnvironmentOperating: 0 to 50 °C (32 to 122 °F)Storage: -20 to 70 °C (-4 to 1

Strona 88

Appendix C. Specifications SummaryC-4 MX2810 M13 User Manual 61185001L1-1

Strona 89

61185001L1-1 MX2810 M13 User Manual D-1Appendix DAcronyms/AbbreviationsACO ... alarm cut offACT... activeAIS...

Strona 90

Chapter 1. Introduction1-2 MX2810 M13 User Manual 61185001L1-1The major features of the MX2810 are as follows:• Built-in 1:1 redundancy• Hot-swappable

Strona 91 - DS2 Statistics

Appendix D. Acronyms/AbbreviationsD-2 MX2810 M13 User Manual 61185001L1-1CSES... C-bit severely errored secondsCSU ...

Strona 92

Appendix D. Acronyms/Abbreviations61185001L1-1 MX2810 M13 User Manual D-3LAIS ... loop side alarm indication signalLAN...

Strona 93 - T1/E1 Statistics

Appendix D. Acronyms/AbbreviationsD-4 MX2810 M13 User Manual 61185001L1-1PVC ... permanent virtual circuitRD... rec

Strona 94 - PROTECTION SWITCH STATISTICS

61185001L1-1 MX2810 M13 User Manual E-1Appendix EGlossary10BaseTEthernet connector which implements the IEEE standard on 24-gauge, unshielded twisted-

Strona 95

Appendix E. GlossaryE-2 MX2810 M13 User Manual 61185001L1-1bipolarA signal containing both positive and negative amplitude components.bipolar violatio

Strona 96

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-3C-bitAn overhead bit in the DS3 string not used for framing, parity, or alarm indica-tion.C

Strona 97 - Loopbacks

Appendix E. GlossaryE-4 MX2810 M13 User Manual 61185001L1-1craft portThe electrical interface between the MX2810 and the control terminal. The con-tro

Strona 98 - Tributary

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-5delayThe amount of time by which a signal is delayed. A round-trip transmission delay measu

Strona 99

Appendix E. GlossaryE-6 MX2810 M13 User Manual 61185001L1-1ethernet Transmission protocol for packet-switching LANs. facilitiesThe equipment used by c

Strona 100 - Remote Loopback

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-7LANLocal area network. A privately owned network that offers high-speed commu-nications cha

Strona 101 - CSU Loopback w/BERT

Chapter 1. Introduction61185001L1-1 MX2810 M13 User Manual 1-310BaseT local area network (LAN) port. The MX2810 supports the MIB-II standard, RFC 1213

Strona 102 - Line BERT

Appendix E. GlossaryE-8 MX2810 M13 User Manual 61185001L1-1NCNormally closed. Relay switch contacts that remain closed when inactive.near endThe unit

Strona 103 - DS3 LOOPBACKS

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-9red alarmUnframed all ones signal (keep alive signal). A red alarm is declared on detec-tio

Strona 104 - Network Loopback

Appendix E. GlossaryE-10 MX2810 M13 User Manual 61185001L1-1SRData set ready. A signal on the DTE interface that indicates if a connection exists and

Strona 105 - DS2 LOOPBACKS

Appendix E. Glossary61185001L1-1 MX2810 M13 User Manual E-11WANWide area network. A communications network serving geographically separate areas. A WA

Strona 106 - DS2 Network

Appendix E. GlossaryE-12 MX2810 M13 User Manual 61185001L1-1

Strona 107 - Circuit Redundancy

61185001L1-1 MX2810 M13 User Manual Index-1IndexNumerics10BaseT connection, location of 2-724 Hour Alarm HistoryDS2 Statistics menu 5-9DS3 Statistics

Strona 108 - NON-REDUNDANT MODE

IndexIndex-2 MX2810 M13 User Manual 61185001L1-1BERTCSU Loopback w/ 6-5Line 6-6Bipolar Violations 5-11blue alarmDS2 State 4-7network state 4-2Remote s

Strona 109 - CIRCUIT FAILURE RECOVERY MODE

Index61185001L1-1 MX2810 M13 User Manual Index-3DS2 State 4-7AIS 4-7LOF 4-7OK 4-7RAI 4-7DS2 Statistics menu 5-9DS3 Alarm Traps Far-end Active Cards 3-

Strona 110 - Chapter 7. Circuit Redundancy

IndexIndex-4 MX2810 M13 User Manual 61185001L1-1Interface menu, T1/E1 3-6Interval starting at:, Performance Parameters (DS3) 5-6IOX PROGRAM FAILURE 3-

Strona 111 - Power Loss Recovery

Index61185001L1-1 MX2810 M13 User Manual Index-5MIB II Standard Alarm Traps 3-20Authentication Failure 3-20Cold Start 3-20Link Down 3-20Link Up 3-20MI

Strona 112 - NON-REDUNDANT POWER MODE

Trademark InformationOpenView is a trademark of Hewlett-Packard Company.Spectrum is a registered trademark of Cabletron.901 Explorer BoulevardP.O. Box

Strona 113 - POWER SUPPLY RECOVERY MODE

Chapter 1. Introduction1-4 MX2810 M13 User Manual 61185001L1-1TL1Transaction Language 1 (TL1) is an ASCII based language that supports both command-re

Strona 114

IndexIndex-6 MX2810 M13 User Manual 61185001L1-1Power Supply Alarm Traps 3-17Card Removed 3-17Malfunction 3-17Power Low 3-17Temperature Critical 3-17T

Strona 115 - BATTERY BACKUP MODE

Index61185001L1-1 MX2810 M13 User Manual Index-7specifications, MX2800 C-1Stand By, Card A/Card B 4-6State menu (DS3 State) 4-2State menus, T1/E1 3-6S

Strona 116

IndexIndex-8 MX2810 M13 User Manual 61185001L1-1TL1 9-1alarm events 9-17autonomous messages 9-17, 9-22commands 9-11Editing 9-23error codes 9-23informa

Strona 119

Chapter 1. Introduction61185001L1-1 MX2810 M13 User Manual 1-5E1 Patch Panel (P/N 1200291L5)The optional E1 patch panel (see Figure 1-1) connects to t

Strona 120 - TL1 MESSAGES

Chapter 1. Introduction1-6 MX2810 M13 User Manual 61185001L1-1

Strona 121 - TL1 Responses

61185001L1-1 MX2810 M13 User Manual 2-1Chapter 2Installation and OperationUNPACK, INSPECT, POWER UPReceiving InspectionCarefully inspect the MX2810 fo

Strona 122

Chapter 2. Installation and Operation2-2 MX2810 M13 User Manual 61185001L1-1Power UpThe MX2810 is powered using a -48V DC power source. The rear pane

Strona 123

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-3Table 2-1. DC Connector Symbol DefinitionsPower RequirementsTable 2-2 pro

Strona 124

Chapter 2. Installation and Operation2-4 MX2810 M13 User Manual 61185001L1-1The following UL requirements must be met during installation of the MX281

Strona 125

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-5RACKMOUNT INSTALLATIONThe MX2810 can be mounted into a standard 19-inch or

Strona 126

Chapter 2. Installation and Operation2-6 MX2810 M13 User Manual 61185001L1-1.Figure 2-2. The Breakout PanelConnecting the E1 Patch PanelThe optional

Strona 127 - ALW-MSG-{EQPT

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-7equipment. Descriptions for these items follow the figure. Pin assignment

Strona 128 - CANC-USER;

61185001L1-1 MX2810 M13 User Manual iiiFCC regulations require that the following information be provided in this manual:1. This equipment complies wi

Strona 129 - INH-MSG-{EQPT

Chapter 2. Installation and Operation2-8 MX2810 M13 User Manual 61185001L1-1Critical, Major, and Minor Alarm ConnectorsConnectors for critical, major,

Strona 130 - RTRV-ALM-{EQPT

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-9FRONT PANELThe MX2810 front panel is shown in Figure 2-4. Descriptions of

Strona 131

Chapter 2. Installation and Operation2-10 MX2810 M13 User Manual 61185001L1-1active controller card or the controller card on standby. The following t

Strona 132 - RTRV-COND-{EQPT

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-11T1/E1 Status LEDsThese LEDs apply to each individual T1 or E1. Different

Strona 133 - TL1 Autonomous Messages

Chapter 2. Installation and Operation2-12 MX2810 M13 User Manual 61185001L1-1Table 2-5. T1/E1 LED ConditionsLED State T1/E1 ConditionActive Cardgreen

Strona 134

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-13Craft PortThe CRAFT port provides connection to a VT100 EIA-232 compatibl

Strona 135

Chapter 2. Installation and Operation2-14 MX2810 M13 User Manual 61185001L1-1 Figure 2-5. Terminal Main MenuNavigating Within the MenusNavigate withi

Strona 136

Chapter 2. Installation and Operation61185001L1-1 MX2810 M13 User Manual 2-15The MX2810 MAIN menu consists of the following sections: StatusProvides i

Strona 137

Chapter 2. Installation and Operation2-16 MX2810 M13 User Manual 61185001L1-1

Strona 138

61185001L1-1 MX2810 M13 User Manual 3-1Chapter 3ConfigurationTo configure the MX2810, use a 10BaseT ethernet connection or a VT100 terminal. Figure 3-

Strona 139 - TL1 Editing

iv MX2810 M13 User Manual 61185001L1-1Federal Communications CommissionRadio Frequency Interference StatementThis equipment has been tested and found

Strona 140

Chapter 3. Configuration3-2 MX2810 M13 User Manual 61185001L1-1Figure 3-2. Configuration Menu Tree1. Network Interface2. T1/E1 Interface4. UtilitiesD

Strona 141

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-3NETWORK INTERFACESelect NETWORK INTERFACE to access the network configuration parameter

Strona 142

Chapter 3. Configuration3-4 MX2810 M13 User Manual 61185001L1-1Remote LoopbacksSelect FEAC/C-BIT to allow the MX2810 to respond to remote loopback req

Strona 143

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-5Protection ConfigurationThe MX2810 houses two controller cards for 1:1 protection again

Strona 144

Chapter 3. Configuration3-6 MX2810 M13 User Manual 61185001L1-1The fourth T1/E1 port of the selected group is not available in this mode. Any combinat

Strona 145

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-7Figure 3-5. T1/E1 State MenuSet MultipleUse SET MULTIPLE (see Figure 3-6 on page 3-7)

Strona 146

Chapter 3. Configuration3-8 MX2810 M13 User Manual 61185001L1-1T1/E1 Line CodingSet the line code for each individual T1/E1 interface to match the con

Strona 147

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-9Figure 3-8. T1/E1 Line Length MenuT1/E1 Loopback DetectionChoose which T1/E1 lines wil

Strona 148

Chapter 3. Configuration3-10 MX2810 M13 User Manual 61185001L1-1T1/E1 Circuit ProtectionT1/E1 Circuit Protection determines which circuit will be allo

Strona 149

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-11Figure 3-11. Line Identification MenuXCV ThresholdSet a limit on code violations (CVs

Strona 150

61185001L1-1 MX2810 M13 User Manual vCanadian Equipment LimitationsNotice: The Canadian Industry and Science Canada label identifies certified equip-

Strona 151

Chapter 3. Configuration3-12 MX2810 M13 User Manual 61185001L1-1SYSTEM MANAGEMENTConfigure the MX2810 for management through SNMP, TELNET, or a VT100

Strona 152

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-13Subnet MaskEnter the subnet mask of the MX2810. This address is available from your ne

Strona 153 - Acceptance Test Procedure

Chapter 3. Configuration3-14 MX2810 M13 User Manual 61185001L1-1DS3 AlarmsDS2 AlarmsSystem Alarms Alarm DescriptionRAI (Major) The unit is re

Strona 154

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-15T1/E1 Alarms Power Supply AlarmsT1/E1 alarms are cleared when the T1/E1 is dis

Strona 155

Chapter 3. Configuration3-16 MX2810 M13 User Manual 61185001L1-1SNMP Management OptionsTrap IP AddressesEnter up to five IP addresses of SNMP managers

Strona 156

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-17Power Supply Alarm Traps Trap If enabled, the unit issues a trap when...Card Removed t

Strona 157

Chapter 3. Configuration3-18 MX2810 M13 User Manual 61185001L1-1DS3 Alarm Traps (Near-End Active and Standby Cards) Trap If enabled, the unit issues a

Strona 158

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-19DS3 Alarm Traps (Far-End Active Cards)DS2 Alarm Traps Trap If enabled, the unit issues

Strona 159

Chapter 3. Configuration3-20 MX2810 M13 User Manual 61185001L1-1T1/E1 Alarm Traps MIB II Standard Alarm Traps Trap If enabled, the unit issues a trap

Strona 160

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-21Read Community NameEnter the authentication strings used for SNMP management. Match th

Strona 161

vi MX2810 M13 User Manual 61185001L1-1Warranty and Customer ServiceADTRAN will replace or repair this product within the warranty period if it does no

Strona 162

Chapter 3. Configuration3-22 MX2810 M13 User Manual 61185001L1-1AdminThe user may view and/or alter all menu items. Only a user with an Admin user ac

Strona 163

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-23Loopback timeout X X XDS2 #1-7 mode (T1 or E1) X X XConfiguration – T1/E1 Interface me

Strona 164

Chapter 3. Configuration3-24 MX2810 M13 User Manual 61185001L1-1Terminal timeout XIP security XIP hosts XDate XTime XCircuit Identification menu XSysl

Strona 165

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-25Terminal Time OutSet the amount of time the terminal or TELNET session remains inactiv

Strona 166

Chapter 3. Configuration3-26 MX2810 M13 User Manual 61185001L1-1Figure 3-15. Equipment Identification MenuUnit IDProvides a user-configurable text st

Strona 167

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-27Host IP AddressSpecifies the IP address of the external server that is running the Sys

Strona 168 - (TRAFFIC READINESS)

Chapter 3. Configuration3-28 MX2810 M13 User Manual 61185001L1-1Autoprogram CardsEnable this function to allow the controller cards to automatically u

Strona 169 - MX2810 ATP CHECKLIST/SIGN-OFF

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-29UTILITIESThe UTILITIES menu (see Figure 3-16) allows you to view MX2810 system informa

Strona 170

Chapter 3. Configuration3-30 MX2810 M13 User Manual 61185001L1-1Loading Default SettingsSelect LOAD DEFAULT SETTINGS from the UTILITIES menu. Once the

Strona 171 - Appendix B

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-31Update Via XMODEMUpdating the FLASH Software via XMODEM requires that a VT100 terminal

Strona 172 - Appendix B. Pinouts

61185001L1-1 MX2810 M13 User Manual viiTable of ContentsList of Figures ...

Strona 173 - DSX1/E1 Amp connectors

Chapter 3. Configuration3-32 MX2810 M13 User Manual 61185001L1-1select either IMMEDIATE RESET to immediately reset the system or SCHEDULE RESET TIME t

Strona 174

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-33 5. The system must be manually reset after downloading new software for the active c

Strona 175 - Specifications Summary

Chapter 3. Configuration3-34 MX2810 M13 User Manual 61185001L1-1Saving to a TFTP ServerTo save current configuration information to a TFTP server, fol

Strona 176

Chapter 3. Configuration61185001L1-1 MX2810 M13 User Manual 3-353. Select LOAD AND USE CONFIG.Resetting the SystemThe system must be manually reset af

Strona 177

Chapter 3. Configuration3-36 MX2810 M13 User Manual 61185001L1-1

Strona 178

61185001L1-1 MX2810 M13 User Manual 4-1Chapter 4StatusView MX2810 status information by selecting 1-STATUS from the MAIN menu (see Figure 4-1). The in

Strona 179 - Acronyms/Abbreviations

Chapter 4. Status4-2 MX2810 M13 User Manual 61185001L1-1StateDisplays the current condition of the network. Possible conditions are listed in the foll

Strona 180

Chapter 4. Status61185001L1-1 MX2810 M13 User Manual 4-3RemoteThis field indicates the current state of the remote MX2810. Possible conditions are giv

Strona 181

Chapter 4. Status4-4 MX2810 M13 User Manual 61185001L1-1POWER SUPPLY STATEThis field indicates which types of power supplies are installed (AC or DC)

Strona 182

Chapter 4. Status61185001L1-1 MX2810 M13 User Manual 4-5SYSTEM STATEThese fields display information regarding the two controller cards. The followi

Strona 183 - Glossary

Table of Contentsviii MX2810 M13 User Manual 61185001L1-1Power Connection...

Strona 184 - Appendix E. Glossary

Chapter 4. Status4-6 MX2810 M13 User Manual 61185001L1-1Card A/Card BThese fields display the current state of the two controller cards. Possible stat

Strona 185

Chapter 4. Status61185001L1-1 MX2810 M13 User Manual 4-7Card CommThis field displays the current state of the communication link between the two contr

Strona 186

Chapter 4. Status4-8 MX2810 M13 User Manual 61185001L1-1ACKNOWLEDGE ALARMS (ACO)This selection allows you to remotely turn off an active alarm. It is

Strona 187

61185001L1-1 MX2810 M13 User Manual 5-1Chapter 5StatisticsVIEWING STATISTICAL INFORMATIONSelect 2-STATISTICS from the MAIN menu to access STATISTICS m

Strona 188

Chapter 5. Statistics5-2 MX2810 M13 User Manual 61185001L1-1DS3 StatisticsThis menu provides submenus for alarm history and performance parameters (se

Strona 189

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-3The following alarm counts are provided in this menu: Condition DescriptionLOS Number of

Strona 190

Chapter 5. Statistics5-4 MX2810 M13 User Manual 61185001L1-1Figure 5-3. DS3 Current Alarm Count ScreenFigure 5-4. DS3 24-Hour Alarm History ScreenPe

Strona 191

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-524-hour history statistics screen, use the left and right arrow keys to scroll through al

Strona 192

Chapter 5. Statistics5-6 MX2810 M13 User Manual 61185001L1-1Figure 5-6. DS3 Performance Parameters (24 Hour History)Figure 5-7. DS3 Performance Para

Strona 193

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-7Errored Seconds-Line (ES-L)Number of seconds in which one or more CVs or one or more LOS

Strona 194

Table of Contents61185001L1-1 MX2810 M13 User Manual ixTerminal Time Out ...

Strona 195

Chapter 5. Statistics5-8 MX2810 M13 User Manual 61185001L1-1Severely Errored Seconds - C-Bit (SESCP-P)Number of seconds with 44 or more CCVs, one or

Strona 196

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-9DS2 Statistics24 Hour Alarm HistoryThe MX2810 keeps track of RAI, OOF, and AIS alarms for

Strona 197

Chapter 5. Statistics5-10 MX2810 M13 User Manual 61185001L1-1Performance ParametersThe performance parameters screen displays a count of parity bit er

Strona 198

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-11T1/E1 StatisticsThe MX2810 keeps track of LOSS OF SIGNAL ALARMS, LINE CODING VIOLATIONS,

Strona 199

Chapter 5. Statistics5-12 MX2810 M13 User Manual 61185001L1-1PROTECTION SWITCH STATISTICSThis menu provides statistics regarding protection switches.

Strona 200

Chapter 5. Statistics61185001L1-1 MX2810 M13 User Manual 5-13system configuration are saved to non-volatile memory. Both the alarm log and system co

Strona 201

Chapter 5. Statistics5-14 MX2810 M13 User Manual 61185001L1-1

Strona 202

61185001L1-1 MX2810 M13 User Manual 6-1Chapter 6LoopbacksThe LOOPBACK menu allows you to initiate loopback tests from the MX2810. Figure 6-1 shows the

Strona 203

Chapter 6. Loopbacks6-2 MX2810 M13 User Manual 61185001L1-1T1/E1 LOOPBACKSAfter you select the number that corresponds with the line you want to test,

Strona 204

Chapter 6. Loopbacks61185001L1-1 MX2810 M13 User Manual 6-3Figure 6-3. Tributary Loopback TestAnalog NetworkAn ANALOG NETWORK loopback test loops the