ADTRAN Tracer TRACER 2 x E1 Podręcznik Użytkownika Strona 258

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 257
DS3 Test
246 AXS-200/805/855
Facility Results
Facility Results
Press , select DSn/PDH, DS3, Results, and the Facility tab.
³ CLEAR: Select CLEAR to reset the
counters, clear the history of
alarms and restart the test time.
³ Test Time displays the time
elapsed since the beginning of
the test. The time is reset when
using the CLEAR button.
³ INSERT: Select all errors to be
injected and the Excessive Zero’s
generation, then press the INSERT button to start the
injection/generation. The INSERT button is not available in Monitor
test mode.
Available errors are Bit Error, F-bit, BPV, C-Bit, P-Bit, and Excessive
Zero’s (Single, Burst, Continuous, or Off).
Available Excessive Zero’s injections are Single, Burst, Continuous,
and Off to stop the event generation. Always press the INSERT button
to apply a new Excessive Zero’s selection.
Przeglądanie stron 257
1 2 ... 253 254 255 256 257 258 259 260 261 262 263 ... 318 319

Komentarze do niniejszej Instrukcji

Brak uwag